R. Stahl, Inc.
The Best Solution to Hazardous Location Instrumentation
|
|
|
|
|
 |
INTRINSPAK® Widely copied, never duplicated:
- Short circuit proof, allows live maintenance.
- Snap-on mounting & grounding, attaches to 35mm DIN rail, the quickest, safest installation method available.
- The lowest resistance available, allows the most power thru the barrier for driving field circuits.
- The lowest leak current available; < 1µA in critical applications, provides the greatest degree of electrical isolation.
- The smallest intrinsic safety barrier.
160ma replaceable fuses, services all models.
- INTRINSPAK® intrinsic safety barriers.
The widest selection in the industry.
|
|
|
|
 |
ICS PAK® Intrinsically Safe Isolators
- Does not need grounding, galvanic isolation eliminates ground loops.
- Electro-Magnetic Interference immune design,
- EMI/RFI complies with IEC 801.1-5
- The best signal to noise ratio available.
- 24Vdc, 24Vac, 120Vac, 220Vac powered.
- Convienently mounts on 35mm DIN rail.
- Small package, only 0.75 inch thick.
- All popular instrumentation configurations available.
|
|
|
|
|
|
 |
ICS Modul®
- Galvanic isolation between input, output & power.
- Simple pre-assembled mounting in module carriers with 16 or 32 signals.
- Plug-in modules handle a wide variety of signals.
- Replaceable without disturbing field wiring.
- EMC/CE compliant.
- Surface orDin rail mount.
- Plug in field termination, custom
configurations available
- DCS ready!
|
|
 |
|
|
|
|
|
|
|
IS-1®
Intrinsically Safe
Distributed I/O System
|
|
|
|
Advantages:
IS-1 Network topology allows I/O about your facility.
Buss, tree & star configurations are possible using copper and fiberoptic technology.
Distributing IS-1 moves the I/O closer to your field devices saving labor and material in installation.
Networked I/O saves 30-40% cost over conventional hard wiring.
Networking solutions include Profibus, Fieldbus Foundation, ControlNet and Modbus. Other solutions available on request.
Input low level signals like TC's & RTD's directly.
Standard:
Installation can be safe area, Div.1/Zone1, Div.2/ Zone2.
All signals are monitored for short/open circuit, full HART support, fault status configurable.
Modules are hot swappable, can be mixed IS and non-IS field circuits, complete system redundancy.
Diagnostic information indicates status of the CPU & I/O as well as any faults on the field wiring.
Highest point density on the I/O modules provide a cost effective solution. |
|
 |
 |
 |
 |
|
|
|